Powerware - 9125 1000-6000VA~

Details & Datasheet...
Powerware 9125 1000VA 1500VA 2000VA3000VA5000VA6000VA
~~~107515~107574~~
Powerware - 9125 1000-6000VA |
New Layout Table~~~~107515~107573~~
Product Header~
CodePowerTopologyVoltageFrequency
~~~107515~107572~~
Powerware - 9125 1000VA~
PW9125-1000VA1000VAOnline 230V 50/60Hz
~As business becomes increasingly dependent on technology for their fundamental operation the need for system availability is of paramount importance.

Powerware 9125 double conversion design makes it optimal for protecting mission-critical Rackmounted IT, Industrial, Medical and Telecommunications applications.

Available in power ratings of up to 6kVA, the Powerware 9125 RM promises premiere protection, longer backup time, remote manageability, installation flexibility and superior service all available in a real rackmount mechanic pack.

Powerware 9125 protects against all nine basic power problems that could harm your equipment or result in corrupted data.

Models available in EMEA: 1000 VA, 1500 VA, 2000 VA, 3000 VA, 5000 VA, 6000 VA.

Online

1

2

3

4

5

Power Failure Power Sag Power Surge Under Voltage Over Voltage

6

7

8

9

Switching transient Line Noise Frequency Variation Harmonic Distortion


Features:

  • Double Conversion technology in real rackmount design
  • 2U high 1000-3000 VA
  • 5U high 6000 VA
  • ABM™ Advance Battery Management prolongs battery life by 50%
  • Connectivity options
  • Extended runtime
  • Powerware Software Suite included
  • Can also be installed as standalone unit



Product Number PW9125-1000VA
Capacity 1000VA / 700W
Dimensions (HxWxD) 432 x 490 x 89 mm
Unit Weight 15 kg
Input Connections IEC320/10A
Output connections 6xIEC320/10A
Operational
Nominal input voltage (Vac)220/230/240 Vac
Input voltage ranges160-288 Vac (1000-3000 VA)
120-288 Vac (6000 VA)
120/140/184-276 Vac (5000-6000 VA)
Operating frequency50/60Hz, Auto-sensing
Input power factor>0.95
Nominal output voltage208/220/230/240 Vac
Output voltage regulation± 3% online; ± 3% on battery mode
Overload capacityUp to 110 % for 2 minute, 111-150% for 30 sec
Efficiency>85% (1000-3000 VA; >90% (6000 VA)
>90% (700 VA); >93% 1000-3000 VA; >95% 5000-6000 VA (High eciency mode)
User interface
LED3 LEDs indigating UPS status
5 Alarm/Bar Graph indicators
Standard communication portsRS232 as standard (1000-3000 VA); RS232 and USB on 6000 VA
OptionalSNMP, Multiserver card, Relay card, Modbus card
Environmental
Operating temperature0°C - +40°C
Storage temperatureRecommended 0°C - +25°C
Altitude<3000 m
Audible noise at 1 metre<45 dB (normal mode)
<50 dB (battery mode)
Certifcation
MarkingsCE & UL 1778 (1000-2000 VA)
CE (3000 VA & 6000 VA)
SafetyEN 50091-1
EMCEN 50091-2
EN 6100-3-2 (1000-3000 VA)


Powerware 9125 UPS

File size 1 MB
    Datasheet     Datasheet


Click on the link below to go to the page where this product can be found.

~1000VA Online 230V 50/60Hz|PW9125-1000VA|~107515~107571~PWB9125, 1U, Rackbox~
Powerware - 9125 1500VA~
PW9125-1500VA1500VAOnline 230V 50/60Hz
~As business becomes increasingly dependent on technology for their fundamental operation the need for system availability is of paramount importance.

Powerware 9125 double conversion design makes it optimal for protecting mission-critical Rackmounted IT, Industrial, Medical and Telecommunications applications.

Available in power ratings of up to 6kVA, the Powerware 9125 RM promises premiere protection, longer backup time, remote manageability, installation flexibility and superior service all available in a real rackmount mechanic pack.

Powerware 9125 protects against all nine basic power problems that could harm your equipment or result in corrupted data.

Models available in EMEA: 1000 VA, 1500 VA, 2000 VA, 3000 VA, 5000 VA, 6000 VA.

Online

1

2

3

4

5

Power Failure Power Sag Power Surge Under Voltage Over Voltage

6

7

8

9

Switching transient Line Noise Frequency Variation Harmonic Distortion


Features:

  • Double Conversion technology in real rackmount design
  • 2U high 1000-3000 VA
  • 5U high 6000 VA
  • ABM™ Advance Battery Management prolongs battery life by 50%
  • Connectivity options
  • Extended runtime
  • Powerware Software Suite included
  • Can also be installed as standalone unit



Product Number PW9125-1500VA
Capacity 1500VA / 1050W
Dimensions (HxWxD) 432 x 490 x 89 mm
Unit Weight 23 kg
Input Connections IEC320/10A
Output connections 6xIEC320/10A
Operational
Nominal input voltage (Vac)220/230/240 Vac
Input voltage ranges160-288 Vac (1000-3000 VA)
120-288 Vac (6000 VA)
120/140/184-276 Vac (5000-6000 VA)
Operating frequency50/60Hz, Auto-sensing
Input power factor>0.95
Nominal output voltage208/220/230/240 Vac
Output voltage regulation± 3% online; ± 3% on battery mode
Overload capacityUp to 110 % for 2 minute, 111-150% for 30 sec
Efficiency>85% (1000-3000 VA; >90% (6000 VA)
>90% (700 VA); >93% 1000-3000 VA; >95% 5000-6000 VA (High eciency mode)
User interface
LED3 LEDs indigating UPS status
5 Alarm/Bar Graph indicators
Standard communication portsRS232 as standard (1000-3000 VA); RS232 and USB on 6000 VA
OptionalSNMP, Multiserver card, Relay card, Modbus card
Environmental
Operating temperature0°C - +40°C
Storage temperatureRecommended 0°C - +25°C
Altitude<3000 m
Audible noise at 1 metre<45 dB (normal mode)
<50 dB (battery mode)
Certifcation
MarkingsCE & UL 1778 (1000-2000 VA)
CE (3000 VA & 6000 VA)
SafetyEN 50091-1
EMCEN 50091-2
EN 6100-3-2 (1000-3000 VA)


Powerware 9125 UPS

File size 1 MB
    Datasheet     Datasheet


Click on the link below to go to the page where this product can be found.

~1500VA Online 230V 50/60Hz|PW9125-1500VA|~107515~107579~PWB9125, 1U, Rackbox~
Powerware - 9125 2000VA~
PW9125-2000VA2000VAOnline 230V 50/60Hz
~As business becomes increasingly dependent on technology for their fundamental operation the need for system availability is of paramount importance.

Powerware 9125 double conversion design makes it optimal for protecting mission-critical Rackmounted IT, Industrial, Medical and Telecommunications applications.

Available in power ratings of up to 6kVA, the Powerware 9125 RM promises premiere protection, longer backup time, remote manageability, installation flexibility and superior service all available in a real rackmount mechanic pack.

Powerware 9125 protects against all nine basic power problems that could harm your equipment or result in corrupted data.

Models available in EMEA: 1000 VA, 1500 VA, 2000 VA, 3000 VA, 5000 VA, 6000 VA.

Online

1

2

3

4

5

Power Failure Power Sag Power Surge Under Voltage Over Voltage

6

7

8

9

Switching transient Line Noise Frequency Variation Harmonic Distortion


Features:

  • Double Conversion technology in real rackmount design
  • 2U high 1000-3000 VA
  • 5U high 6000 VA
  • ABM™ Advance Battery Management prolongs battery life by 50%
  • Connectivity options
  • Extended runtime
  • Powerware Software Suite included
  • Can also be installed as standalone unit



Product Number PW9125-2000VA
Capacity 2000VA / 1400W
Dimensions (HxWxD) 432 x 490 x 89 mm
Unit Weight 23 kg
Input Connections IEC320/10A
Output connections 6xIEC320/10A
Operational
Nominal input voltage (Vac)220/230/240 Vac
Input voltage ranges160-288 Vac (1000-3000 VA)
120-288 Vac (6000 VA)
120/140/184-276 Vac (5000-6000 VA)
Operating frequency50/60Hz, Auto-sensing
Input power factor>0.95
Nominal output voltage208/220/230/240 Vac
Output voltage regulation± 3% online; ± 3% on battery mode
Overload capacityUp to 110 % for 2 minute, 111-150% for 30 sec
Efficiency>85% (1000-3000 VA; >90% (6000 VA)
>90% (700 VA); >93% 1000-3000 VA; >95% 5000-6000 VA (High eciency mode)
User interface
LED3 LEDs indigating UPS status
5 Alarm/Bar Graph indicators
Standard communication portsRS232 as standard (1000-3000 VA); RS232 and USB on 6000 VA
OptionalSNMP, Multiserver card, Relay card, Modbus card
Environmental
Operating temperature0°C - +40°C
Storage temperatureRecommended 0°C - +25°C
Altitude<3000 m
Audible noise at 1 metre<45 dB (normal mode)
<50 dB (battery mode)
Certifcation
MarkingsCE & UL 1778 (1000-2000 VA)
CE (3000 VA & 6000 VA)
SafetyEN 50091-1
EMCEN 50091-2
EN 6100-3-2 (1000-3000 VA)


Powerware 9125 UPS

File size 1 MB
    Datasheet     Datasheet


Click on the link below to go to the page where this product can be found.

~2000VA Online 230V 50/60Hz|PW9125-2000VA|~107515~107580~PWB9125, 1U, Rackbox~
Powerware - 9125 3000VA~
PW9125-3000VA3000VAOnline 230V 50/60Hz
~As business becomes increasingly dependent on technology for their fundamental operation the need for system availability is of paramount importance.

Powerware 9125 double conversion design makes it optimal for protecting mission-critical Rackmounted IT, Industrial, Medical and Telecommunications applications.

Available in power ratings of up to 6kVA, the Powerware 9125 RM promises premiere protection, longer backup time, remote manageability, installation flexibility and superior service all available in a real rackmount mechanic pack.

Powerware 9125 protects against all nine basic power problems that could harm your equipment or result in corrupted data.

Models available in EMEA: 1000 VA, 1500 VA, 2000 VA, 3000 VA, 5000 VA, 6000 VA.

Online

1

2

3

4

5

Power Failure Power Sag Power Surge Under Voltage Over Voltage

6

7

8

9

Switching transient Line Noise Frequency Variation Harmonic Distortion


Features:

  • Double Conversion technology in real rackmount design
  • 2U high 1000-3000 VA
  • 5U high 6000 VA
  • ABM™ Advance Battery Management prolongs battery life by 50%
  • Connectivity options
  • Extended runtime
  • Powerware Software Suite included
  • Can also be installed as standalone unit



Product Number PW9125-3000VA
Capacity 3000VA / 2100W
Dimensions (HxWxD) 432 x 610 x 89 mm
Unit Weight 37 kg
Input Connections IEC320/10A
Output connections
Two load segments
6xIEC320/10A
4xIEC320/10A
Operational
Nominal input voltage (Vac)220/230/240 Vac
Input voltage ranges160-288 Vac (1000-3000 VA)
120-288 Vac (6000 VA)
120/140/184-276 Vac (5000-6000 VA)
Operating frequency50/60Hz, Auto-sensing
Input power factor>0.95
Nominal output voltage208/220/230/240 Vac
Output voltage regulation± 3% online; ± 3% on battery mode
Overload capacityUp to 110 % for 2 minute, 111-150% for 30 sec
Efficiency>85% (1000-3000 VA; >90% (6000 VA)
>90% (700 VA); >93% 1000-3000 VA; >95% 5000-6000 VA (High eciency mode)
User interface
LED3 LEDs indigating UPS status
5 Alarm/Bar Graph indicators
Standard communication portsRS232 as standard (1000-3000 VA); RS232 and USB on 6000 VA
OptionalSNMP, Multiserver card, Relay card, Modbus card
Environmental
Operating temperature0°C - +40°C
Storage temperatureRecommended 0°C - +25°C
Altitude<3000 m
Audible noise at 1 metre<45 dB (normal mode)
<50 dB (battery mode)
Certifcation
MarkingsCE & UL 1778 (1000-2000 VA)
CE (3000 VA & 6000 VA)
SafetyEN 50091-1
EMCEN 50091-2
EN 6100-3-2 (1000-3000 VA)


Powerware 9125 UPS

File size 1 MB
    Datasheet     Datasheet


Click on the link below to go to the page where this product can be found.

~3000VA Online 230V 50/60Hz|PW9125-3000VA|~107515~107581~PWB9125, 1U, Rackbox~
Powerware - 9125 5000VA~
PW9125-5000VA5000VAOnline 230V 50/60Hz
~As business becomes increasingly dependent on technology for their fundamental operation the need for system availability is of paramount importance.

Powerware 9125 double conversion design makes it optimal for protecting mission-critical Rackmounted IT, Industrial, Medical and Telecommunications applications.

Available in power ratings of up to 6kVA, the Powerware 9125 RM promises premiere protection, longer backup time, remote manageability, installation flexibility and superior service all available in a real rackmount mechanic pack.

Powerware 9125 protects against all nine basic power problems that could harm your equipment or result in corrupted data.

Models available in EMEA: 1000 VA, 1500 VA, 2000 VA, 3000 VA, 5000 VA, 6000 VA.

Online

1

2

3

4

5

Power Failure Power Sag Power Surge Under Voltage Over Voltage

6

7

8

9

Switching transient Line Noise Frequency Variation Harmonic Distortion


Features:

  • Double Conversion technology in real rackmount design
  • 2U high 1000-3000 VA
  • 5U high 6000 VA
  • ABM™ Advance Battery Management prolongs battery life by 50%
  • Connectivity options
  • Extended runtime
  • Powerware Software Suite included
  • Can also be installed as standalone unit



Product Number PW9125-5000VA
Capacity 5000VA / 3500W
Dimensions (HxWxD) 440 x 635 x 220 mm
Unit Weight 93 kg
Input Connections Hadwired
Output connections Hadwired
Operational
Nominal input voltage (Vac)220/230/240 Vac
Input voltage ranges160-288 Vac (1000-3000 VA)
120-288 Vac (6000 VA)
120/140/184-276 Vac (5000-6000 VA)
Operating frequency50/60Hz, Auto-sensing
Input power factor>0.95
Nominal output voltage208/220/230/240 Vac
Output voltage regulation± 3% online; ± 3% on battery mode
Overload capacityUp to 110 % for 2 minute, 111-150% for 30 sec
Efficiency>85% (1000-3000 VA; >90% (6000 VA)
>90% (700 VA); >93% 1000-3000 VA; >95% 5000-6000 VA (High eciency mode)
User interface
LED3 LEDs indigating UPS status
5 Alarm/Bar Graph indicators
Standard communication portsRS232 as standard (1000-3000 VA); RS232 and USB on 6000 VA
OptionalSNMP, Multiserver card, Relay card, Modbus card
Environmental
Operating temperature0°C - +40°C
Storage temperatureRecommended 0°C - +25°C
Altitude<3000 m
Audible noise at 1 metre<45 dB (normal mode)
<50 dB (battery mode)
Certifcation
MarkingsCE & UL 1778 (1000-2000 VA)
CE (3000 VA & 6000 VA)
SafetyEN 50091-1
EMCEN 50091-2
EN 6100-3-2 (1000-3000 VA)


Powerware 9125 UPS

File size 1 MB
    Datasheet     Datasheet


Click on the link below to go to the page where this product can be found.

~5000VA Online 230V 50/60Hz|PW9125-5000VA|~107515~107582~PWB9125, 1U, Rackbox~
Powerware - 9125 6000VA~
PW9125-6000VA6000VAOnline 230V 50/60Hz
~As business becomes increasingly dependent on technology for their fundamental operation the need for system availability is of paramount importance.

Powerware 9125 double conversion design makes it optimal for protecting mission-critical Rackmounted IT, Industrial, Medical and Telecommunications applications.

Available in power ratings of up to 6kVA, the Powerware 9125 RM promises premiere protection, longer backup time, remote manageability, installation flexibility and superior service all available in a real rackmount mechanic pack.

Powerware 9125 protects against all nine basic power problems that could harm your equipment or result in corrupted data.

Models available in EMEA: 1000 VA, 1500 VA, 2000 VA, 3000 VA, 5000 VA, 6000 VA.

Online

1

2

3

4

5

Power Failure Power Sag Power Surge Under Voltage Over Voltage

6

7

8

9

Switching transient Line Noise Frequency Variation Harmonic Distortion


Features:

  • Double Conversion technology in real rackmount design
  • 2U high 1000-3000 VA
  • 5U high 6000 VA
  • ABM™ Advance Battery Management prolongs battery life by 50%
  • Connectivity options
  • Extended runtime
  • Powerware Software Suite included
  • Can also be installed as standalone unit



Product Number PW9125-6000VA
Capacity 6000VA / 4200W
Dimensions (HxWxD) 440 x 635 x 220 mm
Unit Weight 93 kg
Input Connections Hadwired
Output connections Hadwired
Operational
Nominal input voltage (Vac)220/230/240 Vac
Input voltage ranges160-288 Vac (1000-3000 VA)
120-288 Vac (6000 VA)
120/140/184-276 Vac (5000-6000 VA)
Operating frequency50/60Hz, Auto-sensing
Input power factor>0.95
Nominal output voltage208/220/230/240 Vac
Output voltage regulation± 3% online; ± 3% on battery mode
Overload capacityUp to 110 % for 2 minute, 111-150% for 30 sec
Efficiency>85% (1000-3000 VA; >90% (6000 VA)
>90% (700 VA); >93% 1000-3000 VA; >95% 5000-6000 VA (High eciency mode)
User interface
LED3 LEDs indigating UPS status
5 Alarm/Bar Graph indicators
Standard communication portsRS232 as standard (1000-3000 VA); RS232 and USB on 6000 VA
OptionalSNMP, Multiserver card, Relay card, Modbus card
Environmental
Operating temperature0°C - +40°C
Storage temperatureRecommended 0°C - +25°C
Altitude<3000 m
Audible noise at 1 metre<45 dB (normal mode)
<50 dB (battery mode)
Certifcation
MarkingsCE & UL 1778 (1000-2000 VA)
CE (3000 VA & 6000 VA)
SafetyEN 50091-1
EMCEN 50091-2
EN 6100-3-2 (1000-3000 VA)


Powerware 9125 UPS

File size 1 MB
    Datasheet     Datasheet


Click on the link below to go to the page where this product can be found.

~6000VA Online 230V 50/60Hz|PW9125-6000VA|~107515~107583~PWB9125, 1U, Rackbox~
Black Product Divider~~~~107515~107570~~
Layout Table~~~~107515~107787~~
Battery Packs~~~~107515~107786~~
Battery Packs |
New Layout Table~~~~107515~107785~~
Product Header~
CodeDescription
~~~107515~107784~~
Powerware - 9125 - EBM - 1000 for 1000VA~
PW9125-EBM-1000Extended Battery Module for 1000VA UPS
~~Powerware - 9125RM - EBM - 1000 for 1000UPS|PW9125-EBM-1000|~107515~107783~PWB5125, 1U, Rackbox~
Powerware - 9125 - EBM - 2000 for 1500/2000VA~
PW9125-EBM-2000Extended Battery Module for 1500/2000VA UPS
~~Powerware - 9125RM - EBM - 2000 for 1500/2000VA UPS|PW9125-EBM-2000|~107515~107788~PWB5125, 1U, Rackbox~
Powerware - 9125 - EBM - 3000 for 3000VA~
PW9125-EBM-3000Extended Battery Module for 3000VA UPS
~~Powerware - 9125RM - EBM - 3000 for 3000VA UPS|PW9125-EBM-3000|~107515~107789~PWB5125, 1U, Rackbox~
Powerware - 9125 - EBM - 6000 for 6000VA~
PW9125-EBM-6000Extended Battery Module for 6000VA UPS
~~Powerware - 9125RM - EBM - 6000 for 6000VA UPS|PW9125-EBM-6000|~107515~107790~PWB5125, 1U, Rackbox~
Black Product Divider~~~~107515~107782~~
Layout Table~~~~107515~107796~~
Rack Mount Kit~~~~107515~107795~~
Rack Mount Kit |
New Layout Table~~~~107515~107794~~
Product Header~
CodeDescription
~~~107515~107793~~
Powerware - 9125 - Rack Mount Kit 2U~
PW9125-RM-2U Rack Mount Kit 2U
~~Powerware - 9125RM - Rack Mount Kit|PW9125-RM-2U|~107515~107792~PWB5125, 1U, Rackbox~
Powerware - 9125 - Rack Mount Kit 6kVA Black~
PW9125-RM-6BL Rack Mount Kit 6kVA (Black)
~~Powerware - 9125RM - Rack Mount Kit 6kVA (Black)|PW9125-RM-6BL|~107515~107797~PWB5125, 1U, Rackbox~
Powerware - 9125 - Rack Mount Kit 6kVA Beige~
PW9125-RM-6BE Rack Mount Kit 6kVA (Beige)
~~Powerware - 9125RM - Rack Mount Kit 6kVA (Beige)|PW9125-RM-6BE|~107515~107798~PWB5125, 1U, Rackbox~
Black Product Divider~~~~107515~107791~~
Layout Table~~~~107515~107803~~
Pedestal Kit~~~~107515~107802~~
Pedestal Kit |
New Layout Table~~~~107515~107801~~
Product Header~
CodeDescription
~~~107515~107800~~
Powerware - 9125 Pedestal Kit 5/6 kVA (Black)~
PW9125-PK-BLPedestal Kit 5/6 kVA (Black)
~~Powerware - 9125 Pedestal Kit 5/6 kVA (Black)|PW9125-PK-BL|~107515~107804~PWB5125, 1U, Rackbox~
Powerware - 9125 Pedestal Kit 5/6 kVA (Beige)~
PW9125-PK-BEPedestal Kit 5/6 kVA (Beige)
~~Powerware - 9125 Pedestal Kit 5/6 kVA (Beige)|PW9125-PK-BE|~107515~107805~PWB5125, 1U, Rackbox~
Black Product Divider~~~~107515~107799~~
Layout Table~~~~107515~107726~~
9125 RM~
Powerware 9125 UPS

File size 1 MB
    Datasheet     Datasheet
~~~107515~107728~~
Menu Page | Toolbar Page |
Frameset Page | Index Page | Table of Contents
EROL - Electronic Retail Online E-commerce shopping cart software